Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the borlabs-cookie domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the unlimited-elements-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the dynamic-content-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260
Spannungs- und Stromausgänge - HiTec Zang
LabManager
Spannungs- und Stromausgänge

Spannungs- und Stromausgänge

Präzise Ansteuerung von Laborgeräten

Dieses LabManager-Einschubmodul dient zur Ansteuerung von Laborgeräten mit analogen Spannungs- oder Stromeingängen für Steuer- und Regelungszwecke. Das Modul verwendet vier 6-polige Tuchelbuchsen nach NAMUR-Standard zur Ausgabe von analogen Signalen. Durch geeignete Skalierung können die logischen Signale in Übereinstimmung mit den physikalischen Zielgrößen gebracht werden.

Das Modul kann zum Ansteuern von Analogstellgliedern eingesetzt werden, z.B.

  • Regelventile
  • Dosierpumpen
  • Rührerdrehzahl
  • Externe Regler für Massendurchfluss, Druck etc.

Technische Daten

Anschlusstyp6-polige Buchse, DIN 45322
Auflösung16 Bit
Spannungsausgänge-10…+10 V, max. 2 mA
Stromausgänge0/4…20 mA
Absolute Messunsicherheit v. E. (im Wartungsintervall)±0,2 % garantiert

Weitere Module

Spannungs- und Stromeingänge mit Speisung

Spannungs- und Stromausgänge

CPU-Modul

Beratung anfordern