Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the borlabs-cookie domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the unlimited-elements-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the dynamic-content-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w00c0d55/hiteczang.formvermittlung.de/wp-includes/functions.php on line 6260
DMS-Brücken-Eingänge - HiTec Zang
LabManager
Strain gauge bridge inputs

Strain gauge bridge inputs

Precision module for GraviDos systems and strain gauge transducers

This slide-in module is suitable for connecting 4 GraviDos dosing systems or strain gauge measuring sensors or load cells, torque transducers etc..

The complex amplifier and six-wire technology guarantees maximum measuring accuracy regardless of the cable length.

The integrated adaptive digital filter technology guarantees robust measurement with high disturbance rejection.

You can use this module, for example, to record:

  • Weight
  • force
  • flow
  • torque

 

Technical data

SignalFor direct connection of strain gauge full bridges
Connection type6-pin socket, type LEMO S1
Resolution (ACD)24-bit
Measuring rangeDepending on the measuring cell
Absolute measurement uncertainty from final value (within the maintenance interval)±0.1 %
Absolute measurement uncertainty from final value±0.01 %
Bridge load330 Ω, other values on request
To captureweight, force, flow, torque, etc.

Further modules

Network interfaces

Digital inputs with sensor supply

Thermocouple inputs

HiBus bus coupler outputs for LabManager, channels 5 to 8

RS-485 serial interfaces

Digital outputs

RS-422 serial interfaces

LabManager